Seminar: How to Successfully Cool High-Density IT Hardware

October 12th, 2007

Seminar: How to Successfully Cool High-Density IT Hardware

We are hosting a seminar on “How to Successfully Cool High-Density IT Hardware” on the 17th and 18th January 2008 in Dublin, Ireland.

This is the first time an Uptime Institute seminar has been delivered in Europe and provides an excellent opportunity to learn industry best practise.

This essential and informative seminar will be delivered by the The Uptime Institutes Dr. Robert Sullivan. As you already are aware, Dr Sullivan is the man who invented the industry standard “Hot-Aisle/Cold-Aisle” server lay-out and was also part of the team who identified the problems of Zinc Whiskers in the data centre.

Dr Sullivan is regarded as one of the leading experts in the world of Data Centre management and his seminars are a “must” for all Data Centre Professionals.

Who should attend?

Anyone involved in the management and maintenance of data centres and server rooms will find this seminar invaluable.

Why attend?

The solutions suggested by The Uptime Institute to the problems of cooling high-density hardware have been demonstrated to have significant effects on the elimination of hot spots and the successful cooling of data centres. This in turn results in far less equipment downtime or total failure, and saves considerable sums of money for any organisation which relies on its data centre or server rooms.
This seminar also provides an excellent opportunity to network with your peers from across Europe.

Structure of Seminar

  • An introduction to the Uptime Institute.
  • Executive Summary of where the industry is headed, what it means to users, and the best practices that need to be employed to take advantage of the new technologies.
  • Expanded information on power projections and best practices for implementation in new facilities.
  • Best practices for cooling today’s equipment and future generations of high density computer equipment
  • Q&A session with delegates and Dr Sullivan
  • Uptime Institute CPD certificate for all attendees
  • Networking opportunities after each day.
  • Full three-course lunch provided each day.

Booking your Place

Places are limited and selling fast, so to book your place please contact us immediately.

The seminar is being held in Dublin, Ireland
Dates: 17th and 18th January 2008

Venue: IMI, Sandyford Road, Dublin 16, Ireland

Tickets
Individual Tickets cost £600 GBP BUY NOW
Group rates are available please contact us for details.

Need Assistance?

Our staff are happy to help you organise flights, accommodation, sight-seeing and anything else you may require.

Contact Details

Dublin, Ireland: +353-(0)1-657-2550
London, UK: +44-(0)207-099-5523
Birmingham, UK: +44-(0)121-314-8415

Email: uk@datacleaneurope.com
Email: Ireland@datacleaneurope.com

Metal Grommets, Desk Power Outlets and Server Cabinet Brush Strip Blanking Panels

July 22nd, 2007

Just a quick update to let everyone know that we have a host of new products in our store these include:

Stylish Oval Desk Grommets available in Satin Nickel, Matt Chrome and Bright Chrome

Range of Oval Metal Desk Grommets


Desk Mounted Power and Data Outlets

Desk Mounted Power & Data Outlets


Brush blanking panels for your Server Cabinet

2u Brush Blanking Panel for Server Cabinet

We also have for a limited time only a SALE on our range of round cable grommets!

We also have a our full range of Floor Tile Lifters / Suction Cup Lifters / Carpet Tile Lifters in stock and ready to ship.

And as always we offer FREE SHIPPING on all orders, so visit the Data Clean Store and start saving time and money!

Technorati Profile

How Cabinets help with Thermal Management in the Data Centre

June 20th, 2007

Brian Donowho gave a talk about how cabinets influence the thermal dynamics of the data centre.

He showed how Koldlok Brush Grommets, reduce bypass airflow (information on Koldlok Guide part 1 and Koldloks Guide part 2) and then explained how his range of Water Cooled Cabinets can help reduce the heat in your data centre.

for those of you who could not make it to the BICSI conference held in Citywest, Dublin, Ireland. The full presentation can be downloaded here.

The_Cabinet’s_Place_in_the_Data_Centre_for_Thermal_Management

So you want a true Hot-Aisle/Cold-Aisle in your Data Centre?

May 21st, 2007

Partitioning off perimeter corridors SAVES ENERGY, which SAVES MONEY!

Creating dedicated “hot and cold aisles” or “rack and row” data center equipment placement configurations with PLENAFORM increases the static pressure delivering a higher volume of cooling through perforated tiles and at a further distance from the CRAC units. The Venturi effect is attained, whereby more air pressure rises in the dedicated cold aisles.

How Plenaform Creates Cold Aisle Below the Raised Access Floor

With the deployment of PLENAFORM, a “VUF” vertical under floor partitioning system, air flow distribution may be directed more efficiently from the CRAC units for maximum equipment air cooling or air blocking requirements in a data center raised floor plenum space.

Installing PLENAFORM to direct air flow from the “source of the air” plenum level, a data centre manager can better achieve a thermally tuned data centre. Integrating PLENAFORM into the data centre design helps to mitigate thermally associated risk to equipment hardware.

The key word here is high density computing and PLENAFORM helps to solve thermal imbalances in your data centre environment simply and inexpensively!

How Plenaform Creates Hot Aisle above the Raised Access Floor
To learn more about PlenaForm please click here: Guide to Plenaform System
To read installation Guidelines for the Plenaform system: Plenaform Installation Guide

Plenaform Under Floor Air Barrier for Data Centres

May 21st, 2007

Do you want to lower your Data Centre energy consumption?

Not a problem with PLENAFORM. Decide where you want the air to flow, snap the panels together at the desired height for the under floor space, drop them in, and attach them to the pedestals.

Improving Static Air Pressure in Your Data Centre

PLENAFORM is a passive and contributory holistic solution that can be easily installed as an effective “VUF” or vertical under floor partitioning system, to direct air flow within the plenum space.

PlenaForm directs the source of the cold air from the CRAC units to where the air is needed most.

PLENAFORM helps to maintain the static pressure further away from a CRAC unit and is a simple solution to cool thermal hot spots in your Data Centre.

Since PLENAFORM is fire-rated they can even be used to make vertical blanking panels between racks or on the sides of open server racks to keep hot air from wrapping around and mixing with the intake air.

Partitioning off perimeter corridors SAVES ENERGY, which SAVES MONEY!

Guiding Airflow to where it is needed in your Data Centre
A flexible, snap together, air flow baffle system which helps to solve dynamic thermal imbalances in data centres.

PLENAFORM is scored both vertically and horizontally so sections can be removed or added onto to meet any height or width requirement. All angles of bend radius may be attained, including inside and outside mounting to raised floor pedestals.

Continuous punch out hole pattern allows attachment to any style raised floor pedestal at any height or width location with cable ties.

PLENAFORM is formed from a flame retardant polypropylene compound that is inert, non-conductive, and non-hygroscopic.

Easy to Install - Right Out of the Box!
  • · Control and Balance Data Center Airflow
  • · Separate Hot Aisles from Cold Aisles
  • · No Installation Tools Required
  • · On-Site Configurable (Width and Height)
  • · Fits ANY Raised Floor Pedestal
  • · Reduces Energy Consumption and Operating Costs
  • · An Inert, Non-Conductive and Non-Hygroscopic Material
  • · Flammability rating of UL V- 0 per UL94
  • · RoHS and WEEE Compliant
  • · An Energy Saving and Thermal Tuning Tool
  • PLENAFORM has many uses:

    1. Seal off below tape auto loaders to stop tape reader condensation.
    2. Seal off under PDU’s.
    3. Works above the floor to stop lateral heat transfers in server racks.
    4. Create dedicated return air paths above ceilings.
    5. Create CRAC extension intake heads.
    Cable Opening in Plenaform System
    Plenaform patched

    Data Centre Air Conditioning Efficiency

    May 19th, 2007

    The guys at CIX.ie have published an interesting white paper that deals with how they plan to maximise the Air Conditioning at their new data centre facility in Cork, Ireland

    1) Utilise Free Cooling - By taking advantage of the of the low out-door temperatures in Ireland.

    2) Maximise Chilled Water Temperature

    3) Eliminate Water Mixing

    4) Eliminate Air Mixing - By utilising a cold aisle containment system (the opposite of the more common hot aisle containment system).

    5) Utilising a low resistance slow speed air path - by taking advantage of the large under floor void and the high ceiling space.

    6) Minimise humidification

    The full white paper can be found here http://www.cix.ie/air-conditioning-efficiency-at-the-cix-data-centre/

    We would also recommend that they fit Koldolk Cable Grommets to reduce by-pass air loss and by using the plenaform under floor air barrier system to direct the cold air to exactly where it is needed.

    We look forward to following the progress of the new Data Centre Build.

    Guide to Surface Mounted Koldloks

    May 6th, 2007

    This is Part 2 of our guide to the Koldok range of Products

    Part 1 can be found here

    The KoldLok Surface Mount (Model 2020) is for existing holes with cables already in place.

    It splits apart to encircle the cables and then snaps together as one piece. The unit is then adhered to the top of the tile with the included adhesive mounting kit.

    The KoldLok Surface Mount offers all the features of the Integral (with the exception of the NFPA requirement), but with the added benefit of easily sealing holes without having to disconnect existing cabling.

    Since it is mounted on top of the tile, it seals any size or configuration of opening in the tile up to10″ x 7″ in size. The KoldLok Surface Mount L (Model 2030) and XL, (Model 2040) include metal plates for sealing larger openings.

    The KoldLok Surface L seals openings up to 10″ x 10″ and the XL seals openings up to 10″ x 13″.

    Koldlok Split Surface Mount -  Raised Floor Grommet - Model 2020

    The KoldLok Integral Raised Floor Grommet Range

    May 5th, 2007

    Guide to Koldloks - Part 1

    The KoldLok Integral (Model 1010) is for new cable cut-outs and is designed to seal openings before any equipment has been installed on the raised-floor tile.

    The KoldLok Integral sits flush with the floor into an opening approximately 9″x6″ or 235mm x 172mm .

    The benefits and features of the Integral include a penetrable seal that allows re-cabling with automatic re-sealing, static dissipative properties, and compliance with NFPA requirements to trim cut metal edges of raised-floor tiles. It also assists gas fire suppression systems.

    KoldLok also offers the Split Integral (Model 3030) for existing cabling in raised-floor tiles where the rack clearance is too low to accommodate a Surface Mount unit.
    Special Features of the Integral Units

    • The Split Integral Grommets allow tiles to be moved without capturing cable
    • The Grommets integrate with the raised-floor static dissipation system
    • 32 square inch usable cabling area accommodates a variety of cabling requirements, including 100 amp power connectors
    • The Grommets satisfy NFPA 75 Section 5-4.4 requirement by self-dressing the raw metal edges of raised-floor tile cable cutouts
    • The Grommets contain no loose or partially fastened parts, which can become separated or fall through the raised floor.
    • Compliant with the directive that restricts the use of certain hazardous substances in electrical and electronic equipment (RoHS)
    Koldlok Integral (Model 1010) Raised Floor Grommet

    Koldlok Integral (Model 1010) Raised Floor Grommet - Drawing

    Raised Floor Grommet - Technical Package.zip

    Koldlok Split Integral Raised Floor Grommet (Model 3030)

    Koldlok Split Integral (Model 3030) Raised Floor Grommet - Technical Package.zip

    Koldlok Split Integral Raised Floor Grommet - Drawing

    Data Centre Performance & Efficiency

    April 13th, 2007

    There are some great discussions going on over at the Slashdot website regarding measuring Data Centre Performance & Efficiency with guys from Intel.

    Data Centre Performance

    http://intel.vendors.slashdot.org/vendor_intel/07/03/26/1329234.shtml

    Data Centre Efficiency
    http://intel.vendors.slashdot.org/vendor_intel/07/03/19/1457218.shtml

    Green Data Centre Design UK & Ireland

    February 24th, 2007

    We have recently been working on a project with Byrne Dixon & Associates in the area of Green Data Centre Design and reduction of energy usage in new and existing data centres.

    We helped Vincent Byrne from Byrne Dixon & Associates model the data centre (underfloor obstructions, machine types, power usage etc) and then he used the tileflow software package to plan how to create a uniform air-flow throughout the room.

    We then supplied and fitted koldloks to cover cable cut-out, supplied and fitted an under floor air barriers to deliver cold air to where it is needed most and supplied and fitted aluminium air-grilles with adjustable dampers to direct exactly the right amount of cold air to create an efficient and uniform air-balance.

    This increase in air-conditioning efficiency and a more balanced IT thermal load allowed the client to generate a significant saving on their electricity bill.

    Vincent is now working with the client to introduce an Air Economising system which takes advantage of the cold air or “free air” from out-side the building to cool the data centre.

    Studies have shown that using free air to cool your data centre can generally generate an approximate energy saving of 25%
    Attached is a pdf document which out-lines in a little more detail the modelling system used by Vincent.

    If you would like to know more about how we can help you with supplying and fitting Koldloks brush grommets, under floor air barriers and Aluminium Air-Grilles with adjustable dampers as always don’t hesitate to contact us.

    Green Data Centre Design & Data Centre Energy Usage Reduction